Ethernet Remote IO Module(8DIN+4AIN+4DO,High speed pulse counter,pulse output)

<
>

Ethernet Remote IO Module(8DIN+4AIN+4DO,High speed pulse counter,pulse output)

Model no:M150T

The M150T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 700Khz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

Consult QQ
The M150T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.
Ethernet Data Acquisition Module
The M150T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 700Khz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.

The M150T Ethernet Remote I/O module can work at 12~36VDC with anti-reverse protection design. Also, it provides 1channel 12~36VDC power output for external device to save wiring cost.
TagsModbus TCP Remote IO Modulepulse output Remote IO ModuleEthernet Remote IO ModuleData Acquisition Module
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Power supply 12~36VDC with over voltage and phase-reversal protection;
3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
4. Support Web real-time monitoring and Web debugging;  
5. DO1 support PWM output;
6. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
7. 8 optical isolated digital input, supports max. 700Khz high speed pulse counter;
8. 4 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
9. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
10. High sampling frequency and special filtering strategy to ensure reliability;
11. 1 RS485 Serial port, supports Modbus RTU Master or Slave, can extend I/O modules;
12. Supports register mapping function and extend I/O inquiry strategy;
13. Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
14. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
15. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
16. Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

M150T Specifications

 

Ethernet Remote I/O Module Specifications

• Digital Input

Sensor Type

Wet Contact (NPN or PNP), Dry Contact

I/O Mode

DI or Event Counter

Dry Contact

• On: short to GND=1
• Off: open=0

Wet Contact (DI to COM)

• On: 10 to 30 VDC=1
• Off: 0 to 3 VDC=0

Counter Frequency

Max. 700kHz(Only the 1st Channel can be used as high speed pulse counter)

Digital sampling frequency

500Hz

Digital filtering strategy

Continues 3 times

Isolation

Optical Isolated,3k VDC or 2k Vrms

• Digital Output

Type

Sink 

I/O Mode

DO or Pulse Output

Pulse Output Frequency

10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)

Over-Voltage Protection

50 VDC

Over-Temperature Shutdown

175°C (typical), 150°C (min.)

Load Current

Max. 500 mA per channel

Digital sampling frequency

500Hz

Isolation

If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation.

• Analog Input

Type

Differential input

Resolution

12 bits

I/O Mode

Voltage / Current (jumper selectable)

Input Range

0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C

Sampling frequency

20Hz

Built-in Resistor for Current Input

162 ohms

Isolation

Electrical isolation

• Working Power Requirements

Input Voltage

12~36VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

12~36VDC

Output Current

139 mA @ 24 VDC

• LAN

Ethernet

10/100 Mbps, RJ45 ports

Protection

15KV ESD Protection

Protocols

Modbus TCP, TCP/IP,MQTT,TCP Server,TCP Client 

Max. TCP Connection

5

• Serial Port

RS485

MODBUS- RTU Protocol

Protection

15KV ESD Protection

Modbus Slave address

1~255

Baud Rate

1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

Mapping registers

Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m

Ethernet Remote IO Module User Manual :http://rtu-m2m.com/Download/Manual/EN/New_MxxxT_UserManual.zip



Ethernet Remote IO Module Confiurator:http://rtu-m2m.com/Download/Software/EN/New_MxxxT_ConfigurationTool.zip

Win7 8 10 driver:http://rtu-m2m.com/Download/Software/CP210x_Windows7_8_10_Drivers.zip

EMI Standard :

EN55032:2015;

EN 61000-3-2:2014;

EN 61000-3-3:2013;

EMS Standard:

EN 55024:2010+A1:2015;

EN 1000-4-2:2009;

EN61000-4-3:2006+A1:2008+A2:2010;

EN61000-4-4:2012;

EN 61000-4-5:2014;

EN 61000-4-6:2014;

EN 61000-4-8:2010;

EN 61000-4-11:2004;

CE-LVD Standards:

IEC 60950-1:2005+A1:2009+A2:2013;

EN 60950-1:2006+A2:2013;

EN 62311:2008;

EMC:

ETSI EN 301 489-1 V2.2.0(2017-03);

ETSI EN 301 489-17 V3.2.0(2017-03);

ETSI EN 300 328 V2.1.1 (2016-11)。

Modbus TCP Remote IO Module X1
User Manual X1

Typically applications:

 

1.      BTS Monitoring;

2.      Security Alarm System applications;          

3.      Supervision and monitoring alarm systems;

4.      Automatic monitoring system;             

5.      Vending Machines security protection;

6.      Pumping Stations, Tanks, Oil or Water levels;

7.      Buildings and Real Estate;

8.      Weather Stations; 

9.      River Monitoring and Flood Control;

10.   Oil and gas pipelines;  

11.   Corrosion protection

12.   Temperatures, water leakage applications;

13.   Wellheads, boat, vehicle;

14.   Energy saving, street lights control system;

15.   Valve controls;

16.   Transformer stations;   

17.   Unmanned machine rooms;

18.   Control room application;

19.   Automation System, M2M;

20.   Access Control System;

21.  PLC Gateway, PLC Remote Monitoring.