Ethernet Remote AO Output Module (2AO 12bit)

<
>

Ethernet Remote AO Output Module (2AO 12bit)

Model no:M200T

The M200T Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

Consult QQ
The M200T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside.It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems.It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
 AO MODULE
The M200T provides a RS485 interface, through the RS485 bus,it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function,the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

The M200T Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable.
TagsAO ModuleRemote AO Output moduleAO Output Module
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Wide range power supply 24 ~ 36VDC with over voltage and phase-reversal protection;
3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
5. 2 analog output, 12-bit resolution, supports 0-10VDC;
6. High sampling frequency and special filtering strategy to ensure reliability;
7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;
8. Supports register mapping function and extend I/O inquiry strategy;
9. Provides 1 channel 24~36VDC power source output for external device, saving wiring cost;
10. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
11. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field.

Ethernet Remote I/O Module Specifications

• Analog Output

Type

Differential input

Resolution

12 bits

Output Range

0 to 10 VDC

Drive Current

1A (max.)

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C

Load Resistor

Internal register, 400 ohms

Isolation

No

• Working Power Requirements

Input Voltage

24 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

24 to 36 VDC

Output Current

139 mA @ 24 VDC

• LAN

Ethernet

10/100 Mbps, RJ45 ports

Protection

15KV ESD Protection

Protocols

Modbus TCP, TCP/IP

Max. TCP Connection

5

• Serial Port

RS485

MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master only.

Protection

15KV ESD Protection

Modbus Slave address

1~255

Baud Rate

1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

Mapping registers

Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m

Ethernet Remote IO Module User Manual 



Ethernet Remote IO Module Photos 

EMI Standard :

EN55032:2015;

EN 61000-3-2:2014;

EN 61000-3-3:2013;

EMS Standard:

EN 55024:2010+A1:2015;

EN 1000-4-2:2009;

EN61000-4-3:2006+A1:2008+A2:2010;

EN61000-4-4:2012;

EN 61000-4-5:2014;

EN 61000-4-6:2014;

EN 61000-4-8:2010;

EN 61000-4-11:2004;

CE-LVD Standards:

IEC 60950-1:2005+A1:2009+A2:2013;

EN 60950-1:2006+A2:2013;

EN 62311:2008;

EMC:

ETSI EN 301 489-1 V2.2.0(2017-03);

ETSI EN 301 489-17 V3.2.0(2017-03);

ETSI EN 300 328 V2.1.1 (2016-11)。

Modbus TCP Remote IO Module X1
User Manual X1

Typically applications:

1.      BTS Monitoring;

2.      Security Alarm System applications;          

3.      Supervision and monitoring alarm systems;

4.      Automatic monitoring system;             

5.      Vending Machines security protection;

6.      Pumping Stations, Tanks, Oil or Water levels;

7.      Buildings and Real Estate;

8.      Weather Stations; 

9.      River Monitoring and Flood Control;

10.   Oil and gas pipelines;  

11.   Corrosion protection

12.   Temperatures, water leakage applications;

13.   Wellheads, boat, vehicle;

14.   Energy saving, street lights control system;

15.   Valve controls;

16.   Transformer stations;   

17.   Unmanned machine rooms;

18.   Control room application;

19.   Automation System, M2M;

20.   Access Control System;

21.  PLC Gateway, PLC Remote Monitoring.