CANopen/DeviceNet Remote IO Module(1CAN+4RTD,2/3 wires PT100/PT100)

<
>

CANopen/DeviceNet Remote IO Module(1CAN+4RTD,2/3 wires PT100/PT100)

Model no:M240C/M240D

The M240c/M240d CANopen/DeviceNet RTD Remote I/O module provides 4 RTD inputs, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, the resolution is 0.1°C, measure range -120°C ~420°C. All of the I/O with high sampling frequency and special filtering strategy to ensure its reliable. It provides multi I/O, supports standard CANopen/DeviceNet Protocol, can be intergraded into SCADA, OPC server, HMI and other automation systems. It is design for working in the harsh industrial application environment,widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

Consult QQ
The M240c/M240d CANopen/DeviceNet RTD Remote I/O Module is an industrial class, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, provides a CANBus interface. 
It provides multi I/O, supports standard CANopen/DeviceNet Protocol, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
CANopen RTD Remote I/O module
The M240c/M240d CANopen/DeviceNet RTD Remote I/O module provides 4 RTD inputs, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, the resolution is 0.1°C, measure range -120°C ~420°C. All of the I/O with high sampling frequency and special filtering strategy to ensure its reliable.

 The M240c/M240d CANopen/DeviceNet RTD Remote I/O module can work at 12~36VDC with anti-reverse protection design.

MxxxC CANOpen, Mxxxd DeviceNet Series Remote I/O Module Table

DeviceNet

CANOpen

Descriptions

DC Output

Link

M100d

M100c

1 CANBus, 2 DI, 2 AI, 2 DO(Sink) or Relay

1 DC

Details

M110d

M110c

1 CANBus, 4 DI, 4 DO(Sink) or Relay

1 DC

Details

M120d

M120c

1 CANBus, 4 DI, 4 AI, 2AO, 4 DO(Sink) or Relay

1 DC

Details

M130d

M130c

1 CANBus, 8 DI, 4 DO(Sink) or Relay

1 DC

Details

M140d

M140c

1 CANBus, 8 DI, 8 DO(Sink) or Relay

1 DC

Details

M150d

M150c

1 CANBus, 8 DI, 4 AI, 4 DO(Sink) or Relay

1 DC

Details

M160d

M160c

1 CANBus, 8 DI, 8 AI, 8 DO(Sink) or Relay

1 DC

Details

M200d

M200c

1 CANBus, 2AO

1 DC

Details

M210d

M210c

1 CANBus, 4 DI

1 DC

Details

M220d

M220c

1 CANBus, 4 DO(Sink) or Relay

1 DC

Details

M230d

M230c

1 CANBus, 4 AI

1 DC

Details

M240d

M240c

1 CANBus, 4 RTD, 2/3 wire PT100/pt1000

---

Details

M310d

M310c

1 CANBus, 8 DI

1 DC

Details

M320d

M320c

1 CANBus, 8 DO(Sink) or Relay

1 DC

Details

M330d

M330c

1 CANBus, 8 AI

1 DC

Details

M340d

M340c

1 CANBus, 8 RTD, 2/3 wire PT100/pt1000

---

Details

M410d

M410c

1 CANBus, 16 DI

1 DC

Details

M420d

M420c

1 CANBus, 16 DO(Sink) or Relay

---

Details

Notices

1.    If the model provides digital input, the DIN default type: wet contact, optional: dry contact. The input type cannot be changed after manufacturer delivered. The DIN1 default is high-speed count mode, the counter frequency Max. is 1Mhz; it can be changed , , to low-speed count mode by open the shell and change the internal jumper. If require dry contact input, please note when ordering, if DIN1 require high-speed pulse count mode then must be wet contact.

2.    If the model provides digital output, the DO default type: SINK, pulse output frequency is 10Hz~300Khz. optional: Relay. The output type cannot be changed after manufacturer delivered. The DO1 supports PWM high-speed pulse output, the output duty cycle from 10-90%; DO2 can be used to control the direction of the stepper motor. If require relay output, please note when ordering, if DO1, DO2 used for high-speed pulse output then must be Sink.

3.    The model number: M240d/c, M340d/c support thermal resistance temperature transmitter default type: PT100, optional: PT1000, if you need PT1000 type of thermal resistance, please note when ordering.

4.    The valid number of I / O ports corresponding to the model number is described in the Model List, the not included I/O port in the model label is invalid, although in the hardware reserved them.


TagsCANopen Remote IO ModuleHigh Speed Pulse Counter moduledata acquisition module
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Power supply 12~36VDC with over voltage and phase-reversal protection;
3. 1 CANBUS Interface, comply with CANopen specification CiA301,CiA401; 
4. Group 2 Only Server (non UCMM-capable) ;
5. Support Predefined Master/Slave Connection Set;
6. Support CANopen heartbeat and shutdown messages;
7. Provide EDS file for standard CANopen/DeviceNet master interface;
8. 4 RTD input support PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, measure range
 -120°C ~420°C;
9. High sampling frequency and special filtering strategy to ensure reliability;
10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN 35mm industrial rail installation.

CANopen/DeviceNet RTD Remote I/O Module Specifications

• RTD Input

Sensor Type

PT100 or PT1000

Resolution

0.1°C or 0.1 ohm

Input Connection

2- or 3-wire

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C

Sampling frequency

20Hz

Isolation

No

Measurement Range

-120°C ~420°C

• Working Power Requirements

Input Voltage

12~36VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• CANBUS

CANBUS Interface

5.08mm Terminal,

Protection

ESD 500VDC

Wires Connection

Shield Twisted wires, CAN V+, CAN_H, CAN_L, CAN_Shield, GND

CANopen Protocol

CiA301, CiA401

MAC ID

Range:0 ~ 127.

Baud Rate Setting

Range:10, 20, 50, 100, 125, 250, 500, 800kbps, 1Mbps

Predefined Master/Slave Connection Set Rate

Group 2 Only Server

I/O Operation Mode

Polling

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m

CANopen/DeviceNet Remote IO Module User Manual 


CANopen/DeviceNet Remote IO Module Photos

EMI Standard :

EN55032:2015;

EN 61000-3-2:2014;

EN 61000-3-3:2013;

EMS Standard:

EN 55024:2010+A1:2015;

EN 1000-4-2:2009;

EN61000-4-3:2006+A1:2008+A2:2010;

EN61000-4-4:2012;

EN 61000-4-5:2014;

EN 61000-4-6:2014;

EN 61000-4-8:2010;

EN 61000-4-11:2004;

CE-LVD Standards:

IEC 60950-1:2005+A1:2009+A2:2013;

EN 60950-1:2006+A2:2013;

EN 62311:2008;

EMC:

ETSI EN 301 489-1 V2.2.0(2017-03);

ETSI EN 301 489-17 V3.2.0(2017-03);

ETSI EN 300 328 V2.1.1 (2016-11)。

CANopen/DeviceNet Remote IO Module X1
User Manual X1

Typically applications:

1.      BTS Monitoring;

2.      Security Alarm System applications;          

3.      Supervision and monitoring alarm systems;

4.      Automatic monitoring system;             

5.      Vending Machines security protection;

6.      Pumping Stations, Tanks, Oil or Water levels;

7.      Buildings and Real Estate;

8.      Weather Stations; 

9.      River Monitoring and Flood Control;

10.   Oil and gas pipelines;  

11.   Corrosion protection

12.   Temperatures, water leakage applications;

13.   Wellheads, boat, vehicle;

14.   Energy saving, street lights control system;

15.   Valve controls;

16.   Transformer stations;   

17.   Unmanned machine rooms;

18.   Control room application;

19.   Automation System, M2M;

20.   Access Control System;

21.  PLC Gateway, PLC Remote Monitoring.