Cellular Lora Gateway

<
>

Cellular Lora Gateway

Model no:S280

The Lora Gateway S280 can be used for monitoring maximum 400 distributed I/O endpoints though maximum 50 wireless Data Acquisition Modules by wireless lora network. Also it can be used as for converting the meters, transducers, Data Acquisition modules, PLC data via RS485 serial port to wireless lora network and then transmits it to GSM/SMS/GPRS/3G/4G/Ethernet network. It performs as a wired – wireless – SMS/GPRS/ 3G/4G/Ethernet/RS232/RS485 gateway. The range covers about 2~5Km in open air.Supports SMS,GPRS,3G,4G Lte Cellular Networks.Compatible Modbus TCP Protocols and can intergrate to the KPIIOT IoT Cloud Platform and OPC, SCADA and MES systems to build an industiral IoT Solution.

Consult QQ

The Lora Gateway S280 is a cost effective remote terminal unit. It inbuilt cellular module and Lora ISM Band Radio Frequency module, and ARM® Cortex™ 32 Bit RISC Core. It is a multi Isolation I/O port remote terminal unit and wireless data acquisition system.

The Lora Gateway S280 can be used for monitoring maximum 400 distributed I/O endpoints though maximum 50 wireless Data Acquisition Modules by wireless lora network. Also it can be used as for converting the meters, transducers, Data Acquisition modules, PLC data via RS485 serial port to wireless lora network and then transmits it to GSM/SMS/GPRS/3G/4G/Ethernet network. It performs as a wired – wireless – SMS/GPRS/ 3G/4G/Ethernet/RS232/RS485 gateway. The range covers about 2~5Km in open air.

Lora Gateway

The Lora Gateway S280 equips 4 digital inputs, 2 solid relay outputs, power status detection moulde, and onsite temperature and humidity inputs. All of the inputs and outputs are isolation.

The Lora Gateway S280 can be used as Wireless SMS Alarm, when the equipped I/O or 400 distributed I/O alarm occurrence, it also can send pre-definition SMS to up to 10 mobile phone users.

The Lora Gateway S280 is suitable for lots of applications, e.g.: Wireless data logging, BTS monitoring, remote data acquisition, telemetrically, farm, energy saving, agriculture, automatically meter reading system, weather station, storage, factory and other applications.

The Lora Gateway S280 supports Modbus RTU Slave, Modbus TCP, TCP/UDP, SMS and data transparent transmission protocol through RS232/RS485/GSM/SMS/GPRS/3G/4G/Ethernet.

The Lora Gateway S280 can be used as:

  • A Wireless Data Acquisition System. Supports monitoring up to 50 wireless data acquisition module for maximum 400 endpoints by wireless Lora network, the range covers about 2~5Km. Each endpoint can be setup threshold value or alarm conditions, once the value exceed threshold value or activated will send out SMS to alert the users immediately.
  • A Wireless Gateway. Though the WT-01 wireless data transfer unit, it can convert the meters, transducers, Data Acquisition modules, PLC data via RS485 serial port to wireless lora network and then transmits it to GSM/SMS/GPRS/3G/4G/Ethernet network. It performs as a wired – wireless – SMS/GPRS/3G/4G/Ethernet/ RS232/RS485 gateway.
  • A SMS Alarm Controller. The IO activations or deactivations can be reported by SMS and optionally confirmed by phone calls. Each input can have its own message texts and the message can be programmed by users.
  • A Switch with SMS Remote Control. SMS texts for switching particular terminals on/off or pulse output are configurable.
  • A Timer-Switch which can be activated automatically. It can be setup when to performs preset logic events, e.g.: timer reports its status, timer switch on/off device or equipments automatically.
  • A SMS reporter. The Lora Gateway S280 can setup daily automatically report one or more times of its current status to users automatically.
  • A Data Logger. The unit can save all of the events or acquisition data in internal memory storage, the historical data can export to CS format via USB port or upload to server by GPRS /3G /4G network according to schedule, no distance limitation.
  • S280 Lora Gateway & Wireless DAM Table

    Model

    Master/Slave

    Precision

    DIN

    T/H

    DO

    Record

    Communication

    S280

    Master

    12bit

    4

    1

    2

    3500

    USB/RS232/RS485

    433Hz/GSM/GPRS/3G/RJ45

    WT-01

    Slave

    Wireless Data Converter with RS485 Port

    WT-02

    Slave

    -Stop-

    WT-03

    Slave

    Wireless DAM, supports 1 Temperature&Humidity Sensor.

    WT-05

    Slave

    Wireless DAM, supports 1 Temperature&Humidity Sensor and 2 Analog input(0~5V)

    WT-06

    Slave

    Wireless DAM, supports 4 Analog input(0~5V) and 4 Digital Inputs

    Notice

    1.       For 3G Version, the model should plus C or W, C stands for inbuilt module is CDMA2000. W stands for inbuilt module is WCDMA;

    2.  RS232/RS485 serial port default is RS485, optional is RS232.

    3.       T/H: temperature & humidity input for environment monitoring, Range: -40~80°C, 0~100%RH.

    4.       The standard package:

    1x RTU, 1x GSM Antenna, 1x AC/DC Adaptor, Android&IOS Apps, 1x PC Configuration Software,

    1x USB cable, 1x User Manual, 1x Backup battery inside, Terminals for Connection.

    5.      The standard package not includes: SIMCard , Temperature+Humidity sensor AM2301.

     


1.    Inbuilt ARM® Cortex™-M4 32 Bit RISC Core MCU;

2.    Supports GSM/GPRS/3G/4G Cellular networks;

3.    Widely Rated voltage range, 9~36VDC, Inbuilt large capacity rechargeable backup battery;

4.    Large internal memory to save up to 3500 historical records, USB port for configuration, upgrade firmware and export records;

5.    Inbuilt industrial Lora communication module, distance up to 2~5Km;

6.    Supports maximum 50 wireless Data Acquisition Modules, will alert users by SMS once the wireless DAM connect failure to ensure the monitoring working properly;

7.    Supports maximum 400 wireless distributed I/O endpoints;

8.    2 solid relay outputs, rated capacity is 5A/30VDC,5A/250VAC;

9.    4 digital inputs, compatible to dry contact or wet contact inputs. Logic level: 0~0. 5V or short circuit treated as close, +3~30V or open circuits treated as open;

10. 1 temperature & humidity sensor input for monitoring onsite environment, the sensor model is AM2301, Measures temperatures from -40-80°C,0.5°C accuracy, Relative Humidity from 0-99RH%, accuracy is 3%;

11. 1 RS485 serial port (Optional: RS232) for Modbus RTU Slave to SCADA or data transparent transmission;.

12. I/O ports with opto-isolated, RS232/485/RJ45 with 15KV ESD protection;

13. Supports Modbus TCP,TCP/IP protocol, Definition Protocol and transparent transmission over GPRS/3G/ Ethernet network;

14. Automatically resend the data while Cellular/Ethernet communication interrupt or failure, GPRS/3G/4G failure will alert by SMS text to users;

15. Supports remotely restart the RTU, and configure& operate it by SMS commands remotely;

16. Supports over voltage protection and phase-reversal protection, provide DC power sources for external device to save wiring cost;

17. 10 SMS Alert and auto dial numbers for receiving alarm message, can program to receive specified alarm message. 

Item

Reference Scope

DC Power supply

Standard adapter: DC 12V/1.5A  Range 9-36VDC

Power consumption

Standby:12V/70mA;  Working Max.: 12V/300mA

GSM Frequency

850/900/1800/1900Mhz/ 3G WCDMA/3G CDMA2000

Transmit power

Class 4 (2W) at EGSM 900 and EGSM 850

Class 1 (1W) at GSM 1800 and GSM 1900

GPRS connectivity

GPRS multi-slot class 10

GPRS Data Transmission

GPRS data downlink transfer: max. 85.6 kbps

GPRS data uplink transfer: max. 42.8 kbps

Coding scheme: CS-1, CS-2, CS-3 and CS-4

TCP/IP stack

TCP,UDP

SIM interface

Supporting 3V SIM Card

External antenna

SMA Antenna interface, 50 Ohm

Program Interfaces

1 USB Port

Protocols

SMS, GPRS UDP,TCP, Modbus RTU Slave, Modbus TCP and more equipment protocols can be added according to requirements.

RS232/485

1 RS485(Optional: RS232), Support Transparent transmission, definition protocol and Modbus RTU Slave.

RF433Mhz

Inbuilt RF433Mhz Half duplex communication module, wireless distance is 2~5Km, Max. receive sensitive: -148dBm,Max. transmit power: +27dBm.

Max. Wireless DAM

Supports Max. 50 wireless Data Acquisition Modules

Max. Wireless I/O

Supports Max. 400 wireless I/O

RJ45

1 RJ45, support definition protocol and Modbus TCP protocol.

Digital Inputs

4 Digital input, NC/NO/Level type

Temp.&Hum Inputs

Temperature range: -40°C to +80°C. Humidity Range: 0~100%RH;

Relay Outputs

2, Rated: 5A/30VDC,5A/250VAC

Power Outputs

1 Port, 9~36VDC output for external device;

Memory Capacity

Internal Memory inside, can save the data for 3500events.

Backup Battery

3.7V 1200mAH

Temperature range

-10-+70 °C

Humidity range

Relative humidity 95% (condensation free)

Exterior dimension

168mm*113mm*32.3mm

Net Weight

1000 g

Lora Gateway User Manual 



Lora Gateway PC Configuration Tool 



Lora Gateway Photos 



This GSM GPRS 3G 4G Cellular Lora Gateway compatiable belowmetioned certificates and references standards:
EMI Standard :
EN55032:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EMS Standard:
EN 55024:2010+A1:2015
EN 1000-4-2:2009
EN61000-4-3:2006+A1:2008+A2:2010
EN61000-4-4:2012;
EN 61000-4-5:2014;
EN 61000-4-6:2014;
EN 61000-4-8:2010
EN 61000-4-11:2004
CE-LVD Standards:
IEC 60950-1:2005+A1:2009+A2:2013
EN 60950-1:2006+A2:2013
EN 62311:2008
EMC:
ETSI EN 301 489-1 V2.2.0(2017-03)
ETSI EN 301 489-17 V3.2.0(2017-03)
ETSI EN 300 328 V2.1.1 (2016-11)
Lora RTU  X1
AC/DC AdaptorX1
GSM/3G/4G Antenna X1
User Manual X1
PC ConfiguratorX1