Analog Output Modules

2 Analog Output Ethernet Remote Module (2AO 12bit)

Item No.: M200
The M200 Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable.
  • T Version: 1*RJ45+1RS485+2AO
  • E Version: 2*RJ45+1RS485+2AO
  • Introduction Features Specifications Download Applications
    The M200 Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1~2 Industrial 10/100M adaptive Ethernet module inside.It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems.It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
      
    The M200T provides a RS485 interface, through the RS485 bus,it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function,the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

    The M200T Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable.
    1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
    2. Wide range power supply 24 ~ 36VDC with over voltage and phase-reversal protection;
    3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
    4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
    5. 2 analog output, 12-bit resolution, supports 0-10VDC;
    6. High sampling frequency and special filtering strategy to ensure reliability;
    7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;
    8. Supports register mapping function and extend I/O inquiry strategy;
    9. Provides 1 channel 24~36VDC power source output for external device, saving wiring cost;
    10. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
    11. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field.

    Ethernet Remote I/O Module Specifications

    • Analog Output

     

    Type

    Differential input

    Resolution

    12 bits

    Output Range

    0 to 10 VDC

    Drive Current

    1A (max.)

    Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -10 and 60°C
    ±0.5% FSR @ -40 and 75°C

    Load Resistor

    Internal register, 400 ohms

    Isolation

    No

    • Working Power Requirements

    Input Voltage

    24 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

    Input Current

    139 mA @ 24 VDC

    • Power Output

    Output Voltage

    24 to 36 VDC

    Output Current

    139 mA @ 24 VDC

    • LAN

    Ethernet

    10/100 Mbps, RJ45 ports

    Protection

    15KV ESD Protection

    Protocols

    Modbus TCP, TCP/IP

    Max. TCP Connection

    5

    • Serial Port

    RS485

    MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master only.

    Protection

    15KV ESD Protection

    Modbus Slave address

    1~255

    Baud Rate

    1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

    Mapping registers

    Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

    • Physical Characteristics

    Wiring

    I/O cable max. 14 AWG

    Dimensions

    105 x 88 x 30 mm

    Weight

    Under 205 g

    Mounting

    DIN rail or wall

    • Environmental Limits

    Operating Temperature

    Standard Models: -10 to 60°C (14 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

    Storage Temperature

    -40 to 85°C (-40 to 185°F)

    Ambient Relative Humidity

    5 to 95% (non-condensing)

    Altitude

    Up to 3000 m

    Typically applications:

    1.      BTS Monitoring;

    2.      Security Alarm System applications;          

    3.      Supervision and monitoring alarm systems;

    4.      Automatic monitoring system;             

    5.      Vending Machines security protection;

    6.      Pumping Stations, Tanks, Oil or Water levels;

    7.      Buildings and Real Estate;

    8.      Weather Stations; 

    9.      River Monitoring and Flood Control;

    10.   Oil and gas pipelines;  

    11.   Corrosion protection

    12.   Temperatures, water leakage applications;

    13.   Wellheads, boat, vehicle;

    14.   Energy saving, street lights control system;

    15.   Valve controls;

    16.   Transformer stations;   

    17.   Unmanned machine rooms;

    18.   Control room application;

    19.   Automation System, M2M;

    20.   Access Control System;

    21.  PLC Gateway, PLC Remote Monitoring.

    Description
    The M200 Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1~2 Industrial 10/100M adaptive Ethernet module inside.It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems.It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
      
    The M200T provides a RS485 interface, through the RS485 bus,it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function,the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

    The M200T Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable.
    introduction
    The M200 Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
    Features
    1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
    2. Wide range power supply 24 ~ 36VDC with over voltage and phase-reversal protection;
    3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
    4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
    5. 2 analog output, 12-bit resolution, supports 0-10VDC;
    6. High sampling frequency and special filtering strategy to ensure reliability;
    7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;
    8. Supports register mapping function and extend I/O inquiry strategy;
    9. Provides 1 channel 24~36VDC power source output for external device, saving wiring cost;
    10. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
    11. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field.
    Specifications

    Ethernet Remote I/O Module Specifications

    • Analog Output

     

    Type

    Differential input

    Resolution

    12 bits

    Output Range

    0 to 10 VDC

    Drive Current

    1A (max.)

    Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -10 and 60°C
    ±0.5% FSR @ -40 and 75°C

    Load Resistor

    Internal register, 400 ohms

    Isolation

    No

    • Working Power Requirements

    Input Voltage

    24 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

    Input Current

    139 mA @ 24 VDC

    • Power Output

    Output Voltage

    24 to 36 VDC

    Output Current

    139 mA @ 24 VDC

    • LAN

    Ethernet

    10/100 Mbps, RJ45 ports

    Protection

    15KV ESD Protection

    Protocols

    Modbus TCP, TCP/IP

    Max. TCP Connection

    5

    • Serial Port

    RS485

    MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master only.

    Protection

    15KV ESD Protection

    Modbus Slave address

    1~255

    Baud Rate

    1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

    Mapping registers

    Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

    • Physical Characteristics

    Wiring

    I/O cable max. 14 AWG

    Dimensions

    105 x 88 x 30 mm

    Weight

    Under 205 g

    Mounting

    DIN rail or wall

    • Environmental Limits

    Operating Temperature

    Standard Models: -10 to 60°C (14 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

    Storage Temperature

    -40 to 85°C (-40 to 185°F)

    Ambient Relative Humidity

    5 to 95% (non-condensing)

    Altitude

    Up to 3000 m

    Download
    Applications

    Typically applications:

    1.      BTS Monitoring;

    2.      Security Alarm System applications;          

    3.      Supervision and monitoring alarm systems;

    4.      Automatic monitoring system;             

    5.      Vending Machines security protection;

    6.      Pumping Stations, Tanks, Oil or Water levels;

    7.      Buildings and Real Estate;

    8.      Weather Stations; 

    9.      River Monitoring and Flood Control;

    10.   Oil and gas pipelines;  

    11.   Corrosion protection

    12.   Temperatures, water leakage applications;

    13.   Wellheads, boat, vehicle;

    14.   Energy saving, street lights control system;

    15.   Valve controls;

    16.   Transformer stations;   

    17.   Unmanned machine rooms;

    18.   Control room application;

    19.   Automation System, M2M;

    20.   Access Control System;

    21.  PLC Gateway, PLC Remote Monitoring.

    Review