Combination IO Modules

4DIN+4AIN+2AO+4DO Ethernet Remote IO Module

Item No.: M120
M120 Ethernet  Remote I/O Module provides 4 optical-isolated digital inputs, supports Max. 700KMHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal,2 channel 12bits analog outputs, supports 0~10
  • T Version: 1*RJ45+1RS485+4DIN+4AIN+2AO+4DO
  • E Version: 2*RJ45+1RS485+4DIN+4AIN+2AO+4DO
  • Introduction Features Specifications Download Applications
    The M120 Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1-2 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

    The M120T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.
     
    The M120T Ethernet Remote I/O module provides 4 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300KHz high speed pulse output or relay outputs, 2 channel 12bits analog outputs, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.
    1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
    2. Wide range power supply 24 ~ 36VDC with over voltage and phase-reversal protection;
    3. Management and configuration via LAN connection configuration software for easy operation and maintenance, Integrated 10/100M adaptive Ethernet module, supports Modbus TCP,MQTT protocol;
    4. 4 optical isolated digital input, supports max. 700KHz high speed pulse counter;
    5. 4 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
    6. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
    7. 2 analog output, 12-bit resolution, supports 0-10VDC;
    8.High sampling frequency and special filtering strategy to ensure reliability;
    9. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;
    10. Supports register mapping function and extend I/O inquiry strategy;
    11. Provides 1 channel 24~36VDC power source output for external device, saving wiring cost;
    12. LED instructions work status, with reset button to reset, easy on-site installation and  commissioning;
    13. Using metal shell, protection class IP30. Metal shell and system security isolation,  especially suitable for industrial applications in the field;
    14. Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

    M120T Specifications

    Ethernet Remote I/O Module Specifications

    • Digital Input

    Sensor Type

    Wet Contact (NPN or PNP), Dry Contact

    I/O Mode

    DI or Event Counter

    Dry Contact

    • On: short to GND=1
    • Off: open=0

    Wet Contact (DI to COM)

    • On: 10 to 30 VDC =1
    • Off: 0 to 3 VDC=0

    Counter Frequency

    700KHz(Only the 1st Channel can be used as high speed pulse counter)

    Digital sampling frequency

    500Hz

    Digital filtering strategy

    Continues 3 times

    Isolation

    Optical Isolated,3k VDC or 2k Vrms

    • Digital Output

    Type

    Sink 

    I/O Mode

    DO or Pulse Output

    Pulse Output Frequency

    10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)

    Over-Voltage Protection

    50 VDC

    Over-Temperature Shutdown

    175°C (typical), 150°C (min.)

    Load Current

    Max. 500 mA per channel

    Digital sampling frequency

    500Hz

    • Analog Input

    Type

    Differential input

    Resolution

    12 bits

    I/O Mode

    Voltage / Current (jumper selectable)

    Input Range

    0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA

    Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -10 and 60°C
    ±0.5% FSR @ -40 and 75°C

    Sampling frequency

    20Hz

    Isolation

    Electrical isolation

    • Analog Output

    Type

    Differential input

    Resolution

    12 bits

    Output Range

    0 to 10 VDC

    Drive Current

    1A (max.)

    Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -10 and 60°C
    ±0.5% FSR @ -40 and 75°C

    Isolation

    No

    • Working Power Requirements

    Input Voltage

    24 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

    Input Current

    139 mA @ 24 VDC

    • Power Output

    Output Voltage

    24 to 36 VDC

    Output Current

    139 mA @ 24 VDC

    • LAN

    Ethernet

    10/100 Mbps RJ45 ports

    Protection

    15KV ESD Protection

    Protocols

    Modbus TCP, TCP/IP,MQTT, TCP Server, TCP Client 

    Max. TCP Connection

    5

    • Serial Port

    RS485

    MODBUS- RTU Protocol, Modbus-ASCII Protocol

    Protection

    15KV ESD Protection

    Modbus Slave address

    1~255

    Baud Rate

    1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

    Mapping registers

    Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

    • Physical Characteristics

    Wiring

    I/O cable max. 14 AWG

    Dimensions

    105 x 88 x 30 mm

    Weight

    Under 205 g

    Mounting

    DIN rail or wall

    • Environmental Limits

    Operating Temperature

    Standard Models: -10 to 60°C (14 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

    Storage Temperature

    -40 to 85°C (-40 to 185°F)

    Ambient Relative Humidity

    5 to 95% (non-condensing)

    Altitude

    Up to 3000 m

    Typically applications:

     

    1.      BTS Monitoring;

    2.      Security Alarm System applications;          

    3.      Supervision and monitoring alarm systems;

    4.      Automatic monitoring system;             

    5.      Vending Machines security protection;

    6.      Pumping Stations, Tanks, Oil or Water levels;

    7.      Buildings and Real Estate;

    8.      Weather Stations; 

    9.      River Monitoring and Flood Control;

    10.   Oil and gas pipelines;  

    11.   Corrosion protection

    12.   Temperatures, water leakage applications;

    13.   Wellheads, boat, vehicle;

    14.   Energy saving, street lights control system;

    15.   Valve controls;

    16.   Transformer stations;   

    17.   Unmanned machine rooms;

    18.   Control room application;

    19.   Automation System, M2M;

    20.   Access Control System;

    21.  PLC Gateway, PLC Remote Monitoring.

    Description
    The M120 Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1-2 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

    The M120T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.
     
    The M120T Ethernet Remote I/O module provides 4 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300KHz high speed pulse output or relay outputs, 2 channel 12bits analog outputs, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.
    introduction
    M120 Ethernet  Remote I/O Module provides 4 optical-isolated digital inputs, supports Max. 700KMHz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal,2 channel 12bits analog outputs, supports 0~10VDC signal output. 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs.It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
    Features
    1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
    2. Wide range power supply 24 ~ 36VDC with over voltage and phase-reversal protection;
    3. Management and configuration via LAN connection configuration software for easy operation and maintenance, Integrated 10/100M adaptive Ethernet module, supports Modbus TCP,MQTT protocol;
    4. 4 optical isolated digital input, supports max. 700KHz high speed pulse counter;
    5. 4 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
    6. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
    7. 2 analog output, 12-bit resolution, supports 0-10VDC;
    8.High sampling frequency and special filtering strategy to ensure reliability;
    9. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;
    10. Supports register mapping function and extend I/O inquiry strategy;
    11. Provides 1 channel 24~36VDC power source output for external device, saving wiring cost;
    12. LED instructions work status, with reset button to reset, easy on-site installation and  commissioning;
    13. Using metal shell, protection class IP30. Metal shell and system security isolation,  especially suitable for industrial applications in the field;
    14. Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
    Specifications

    M120T Specifications

    Ethernet Remote I/O Module Specifications

    • Digital Input

    Sensor Type

    Wet Contact (NPN or PNP), Dry Contact

    I/O Mode

    DI or Event Counter

    Dry Contact

    • On: short to GND=1
    • Off: open=0

    Wet Contact (DI to COM)

    • On: 10 to 30 VDC =1
    • Off: 0 to 3 VDC=0

    Counter Frequency

    700KHz(Only the 1st Channel can be used as high speed pulse counter)

    Digital sampling frequency

    500Hz

    Digital filtering strategy

    Continues 3 times

    Isolation

    Optical Isolated,3k VDC or 2k Vrms

    • Digital Output

    Type

    Sink 

    I/O Mode

    DO or Pulse Output

    Pulse Output Frequency

    10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)

    Over-Voltage Protection

    50 VDC

    Over-Temperature Shutdown

    175°C (typical), 150°C (min.)

    Load Current

    Max. 500 mA per channel

    Digital sampling frequency

    500Hz

    • Analog Input

    Type

    Differential input

    Resolution

    12 bits

    I/O Mode

    Voltage / Current (jumper selectable)

    Input Range

    0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA

    Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -10 and 60°C
    ±0.5% FSR @ -40 and 75°C

    Sampling frequency

    20Hz

    Isolation

    Electrical isolation

    • Analog Output

    Type

    Differential input

    Resolution

    12 bits

    Output Range

    0 to 10 VDC

    Drive Current

    1A (max.)

    Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -10 and 60°C
    ±0.5% FSR @ -40 and 75°C

    Isolation

    No

    • Working Power Requirements

    Input Voltage

    24 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

    Input Current

    139 mA @ 24 VDC

    • Power Output

    Output Voltage

    24 to 36 VDC

    Output Current

    139 mA @ 24 VDC

    • LAN

    Ethernet

    10/100 Mbps RJ45 ports

    Protection

    15KV ESD Protection

    Protocols

    Modbus TCP, TCP/IP,MQTT, TCP Server, TCP Client 

    Max. TCP Connection

    5

    • Serial Port

    RS485

    MODBUS- RTU Protocol, Modbus-ASCII Protocol

    Protection

    15KV ESD Protection

    Modbus Slave address

    1~255

    Baud Rate

    1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

    Mapping registers

    Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

    • Physical Characteristics

    Wiring

    I/O cable max. 14 AWG

    Dimensions

    105 x 88 x 30 mm

    Weight

    Under 205 g

    Mounting

    DIN rail or wall

    • Environmental Limits

    Operating Temperature

    Standard Models: -10 to 60°C (14 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

    Storage Temperature

    -40 to 85°C (-40 to 185°F)

    Ambient Relative Humidity

    5 to 95% (non-condensing)

    Altitude

    Up to 3000 m

    Download
    Applications

    Typically applications:

     

    1.      BTS Monitoring;

    2.      Security Alarm System applications;          

    3.      Supervision and monitoring alarm systems;

    4.      Automatic monitoring system;             

    5.      Vending Machines security protection;

    6.      Pumping Stations, Tanks, Oil or Water levels;

    7.      Buildings and Real Estate;

    8.      Weather Stations; 

    9.      River Monitoring and Flood Control;

    10.   Oil and gas pipelines;  

    11.   Corrosion protection

    12.   Temperatures, water leakage applications;

    13.   Wellheads, boat, vehicle;

    14.   Energy saving, street lights control system;

    15.   Valve controls;

    16.   Transformer stations;   

    17.   Unmanned machine rooms;

    18.   Control room application;

    19.   Automation System, M2M;

    20.   Access Control System;

    21.  PLC Gateway, PLC Remote Monitoring.

    Review